Composite nanofiltration membrane flatsheet series NaRM

 

Application

Product description

Membrane type NaRM

Specification

Test conditions:

1) 0,5 g/l NaCl solution in water, pressure 0,7 MPa, temperature 25°С.

2) 2,0 g/l MgSO4 solution in water, pressure 0,7 MPa, temperature 25°С.


Operating conditions and technical data for designing
Operation temperature, С1 4-45
рН at operation1 1-12
рН at chemical cleaning (short time operation) 1-13
Acceptable Hydrogen peroxide concentration during continuous operation, mg/l 40
Acceptable Hydrogen peroxide concentration during disinfection (not longer than 30 min, +25°C), mg/l 1000
Acceptable free Chlorine concentration during continuous operation, mg/l 1
Acceptable free Chlorine concentration during disinfection (not longer than 30 min, +25°C, pH 10,5), mg/l 5
SDI (15 minutes test), max 5
Turbidity, NTU max 1
1) During continuous operation with pH over 10 the temperature must not exceed 35°С
Property Standartd, min
Permeate flow, l/m2hr, min 40 40
Rejection by monovalent ions (Cl-)1, %, min 60,00
Rejection by bivalent ions (SO42-)2, %, min 99,0 99,00